StormWater / ADAC Version v4.2

EndStructure

Represents a stormwater endstructure feature as a Point object.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
StructureID String_32
Required

The identifier for this end structure. Usually the textual identifier it would be labelled with on the face of a plan.

StructureLevel_m float
Required

The surface level of the structure in metres against the vertical datum for the project.

EndWall structure
Required

Data structure representing the end wall.

StructureStructure
Type enum
Required

The type of stormwater end wall structure.

Accepted Values
ValueDescription
Type1 MRD Spec Type 1
Type2 MRD Spec Type 2
Type3 MRD Spec Type 3
Construction enum
Required

The method of construction of the end wall structure.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
WingWall structure
Required

Data structure representing the wing wall.

StructureStructure
Type enum
Required

The type of stormwater end wall structure.

Accepted Values
ValueDescription
Type1 MRD Spec Type 1
Type2 MRD Spec Type 2
Type3 MRD Spec Type 3
Construction enum
Required

The method of construction of the end wall structure.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
Apron structure
Required

Data structure representing the apron.

StructureStructure
Type enum
Required

The type of stormwater end wall structure.

Accepted Values
ValueDescription
Type1 MRD Spec Type 1
Type2 MRD Spec Type 2
Type3 MRD Spec Type 3
Construction enum
Required

The method of construction of the end wall structure.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
GrateType enum
Optional

Type of grate used, if applicable.

Accepted Values
ValueDescription
Baffled Baffled
Grated Grated
StillingBasin StillingBasin
Other Other
TideGate enum
Optional

Type of tide or flood gate used, if applicable.

Accepted Values
ValueDescription
FibreglassProprietary FibreglassProprietary
Fabricated Fabricated
Controlled Controlled
Other Other
PredominantMaterial enum
Optional

The predominant construction material of the endstructure.

Accepted Values
ValueDescription
Concrete Concrete
ReinforcedConcrete ReinforcedConcrete
GroutedRock GroutedRock
RevetmentMattress RevetmentMattress
OutletProtectionType enum
Optional

Corrosion protection method employed on the outlet.

Accepted Values
ValueDescription
Grassed Grassed banks
Concrete Concrete
PlacedRock PlacedRock
GroutedRock GroutedRock
RevetmentMattress RevetmentMattress
RockFilledWireBasket RockFilledWireBasket
Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)