StormWater / ADAC Version v6.0.0

EndStructure

Represents a stormwater endstructure feature as a Point object.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
StructureID String_32
Required

The identifier for this end structure. Usually the textual identifier it would be labelled with on the face of a plan.

StructureLevel_m float
Required

The surface level of the structure in metres against the vertical datum for the project.

EndWall boolean
Optional

Data structure representing the end wall. Set to nil if this End Structure does not have an end wall.

truetrue
Type enum
Required

The type of stormwater end wall structure.

Accepted Values
ValueDescription
PipeEndwall PipeEndwall
BoxEndwall BoxEndwall
MultiCellPipeEndwall MultiCellPipeEndwall
MultiCellBoxEndwall MultiCellBoxEndwall
MultiCellPipeAndBoxEndwall MultiCellPipeAndBoxEndwall
SlopingPipeEndwall SlopingPipeEndwall
Size String_32
Required

Define the number of cells and sizes penetrating the End Structure. ie. 3/750 or 2/1200x900 or 2/900x600+1/600.

Length_m Float_Positive_Zero
Required

Represents the length in metres of the end wall.

Height_m Float_Positive_Zero
Required

Represents the height in metres of the end wall.

Thickness_m Float_Positive_Zero
Required

Represents the Thickness in metres of the end wall.

Material enum
Required

The predominant construction material of the end wall structure.

Accepted Values
ValueDescription
Concrete Concrete
ReinforcedConcrete ReinforcedConcrete
GroutedRock GroutedRock
RevetmentMattress RevetmentMattress
NA Not Applicable – To be used if not present
Construction enum
Required

The method of construction of the end wall structure.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
OutletProtection boolean
Optional

Data structure representing the outlet protection. Set to nil if this End Structure does not have any protection.

truetrue
Material enum
Required

Material used for the Outlet Protection.

Accepted Values
ValueDescription
Grassed Grassed
Concrete Concrete
StonePitched StonePitched
PlacedRock PlacedRock
GroutedRock GroutedRock
RevetmentMattress RevetmentMattress
RockFilledWireBasket RockFilledWireBasket
Geotextile Geotextile
ConcreteEnergyDissepiment ConcreteEnergyDissepiment
Area_m2 Float_Positive_NonZero
Optional

The Outlet Protection area, in square metres.

GrateType enum
Optional

Type of grate used, if applicable.

Accepted Values
ValueDescription
Baffled Baffled
Grated Grated
StillingBasin StillingBasin
None No grate fitted
TideGate enum
Optional

Type of tide or flood gate used, if applicable.

Accepted Values
ValueDescription
FibreglassProprietary FibreglassProprietary
Fabricated Fabricated
Controlled Controlled
Rubber Rubber
None No tidegate fitted