WaterSupply / ADAC Version v4.2

Valve

Represents a water supply valve feature.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
Use enum
Required

The purpose of the valve in the network.

Accepted Values
ValueDescription
Control Control Valve. Default Value
ZoneBoundary Zone Boundary Valve. Defines the boundary of a pressure zone or distribution maintenance area.
Service Service Valve.
Type enum
Required

The type of valve.

Accepted Values
ValueDescription
Air Air Valve.
Ball Ball Valve.
Scour Scour Valve.
Reflux Reflux Valve.
SwingCheck Swing Check Valve. Used to prevent backflow within a pipeline.
Altitude Altitude Valve.
PressureReducing Pressure Reducing Valve.
PressureSustaining Pressure Sustaining Valve.
PressureRelief Pressure Relief Valve.
Gate Gate Valve. Used for the isolation of sections and branches in pipelines.
Control A generic or unknown type of control valve.
Butterfly Butterfly Valve.
Stop Stop Valve.
TrunkReflux Trunk Reflux Valve.
Diameter_mm positiveInteger
Required

Diameter in millimetres.

Manufacturer String_64
Optional

The Manufacturer of the unit.

Accepted Values
ValueDescription
Tyco Tyco Flow Control Pacific Pty Ltd. For product listings and details visit http://tycowater.com
John John
Turnflo Turnflo
Keystone Keystone
Watts Watts
Crevet Crevet
ModelNumber String_64
Optional

The standard code, model number or part number for the unit.

Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)

WaterQuality enum
Required

The quality of the water in the network the valve is part of.

Accepted Values
ValueDescription
DrinkingWater Drinking-quality (potable) water for normal mains supply by the municipal water service provider.
RecycledAplus Class A+ tertiary treated with reverse osmosis recycled water for supply via dual reticulation for permitted interior and exterior uses.
RecycleA Class A tertiary treated recycled water for supply via dual reticulation for permitted exterior uses.
TreatedEffluent Treated Effluent to class B through class D for irrigation only.
RainWater Rain Water collected directly into the system for irrigation.
RawWater Untreated water from a watercourse or pond used to feed a water treatment plant or irrigation system.
GroundWater Untreated water from bores used to feed a water treatment plant or irrigation system.
ProcessWater Non-potable process water of some description.
Other Pipe conveying some other kind of water (not recycled class B and below which is considered as treated sewage effluent).
Unknown Type of water carried by this pipe is unknown at time of submission.