WaterSupply / ADAC Version v6.0.0

Hydrant

Represents a water supply hydrant feature.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
Use enum
Required

The purpose of the hydrant in the network.

Accepted Values
ValueDescription
Spring Spring Hydrant.
FillingPoint Hydrant (usually of spring type) with a metered standpipe semi-permanently in place.
Duckfoot End of line with bend at base of riser.
Pillar Pillar Hydrant.
Diameter_mm positiveInteger
Required

The nominal bore size of the hydrant.

Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)

WaterQuality enum
Required

The quality of the water being delivered through the hydrant.

Accepted Values
ValueDescription
DrinkingWater Drinking-quality (potable) water for normal mains supply by the municipal water service provider.
RecycledAplus Class A+ tertiary treated with reverse osmosis recycled water for supply via dual reticulation for permitted interior and exterior uses.
RecycleA Class A tertiary treated recycled water for supply via dual reticulation for permitted exterior uses.
TreatedEffluent Treated Effluent to class B through class D for irrigation only.
RainWater Rain Water collected directly into the system for irrigation.
RawWater Untreated water from a watercourse or pond used to feed a water treatment plant or irrigation system.
GroundWater Untreated water from bores used to feed a water treatment plant or irrigation system.
ProcessWater Non-potable process water of some description.
Other Pipe conveying some other kind of water (not recycled class B and below which is considered as treated sewage effluent).
Unknown Type of water carried by this pipe is unknown at time of submission.