The fitting type.
WaterSupply / ADAC Version v5.0.1
Fitting
Represents a water supply pipe fitting, other than a valve, meter or hydrant
ADAC Versions
Attributes
Required and optional XML attributes
Type
enum
Required
ValueDescription
Bend
Bend, a fitting not a recurved pipe that changes the direction of a pipeline
Connector
A straight through connector with no change of direction
Cross Connection
A cross connection with 4 branches
Connector Thrust
A straight through connector with no change of direction capable of transmitting axial thrust to the pipeline or a structure
Dismantling Joint
A straight connector specifically included to facilitate the dismantling of complex flanged pipework and valves.
Gibault
Standard gibault connection
Taper
Taper. Joining pipes of unequal diameter.
Tee
T - Joint with 3 arms one of which is at right angles to the axis joining the other 2.
Wye
Y - Joint with 3 arms where the angle between any 2 arms is not 90 or 180 degrees
Cathodic Protection Point
Electrical connection point for cathodic protection
Dead Plate
Blank flange on the end of a flanged pipe or fitting
External Dead End
Fitting such as an endcap that forms a dead end in a pipe run
Tee Branch Dead End
A dead end plate pre-fitted to one branch of a Tee for access or future connection
Tee Branch Ext Dead End
Dead end on a Tee fitting with a side branch of extended length
Puddle Flange
Puddle Flange on pipe to transmit thrust or seal pipe into a structure
Ready Tap
Ready Tap collar with prefabricated water service take off points
Sampling Point
Sampling Point to sample water quality
Booster Pump
Booster Pump to boost pressure or provide motive force to water in the network
Surge Vessel
Surge Vessel fitted to control surge pressures (water hammer)
Tapping Band
Tapping Band for the off-take of a water service from a main
Flush Point
Flush Point
Saddle
Saddle
Material
enum
Required
The fitting material.
Accepted Values
ValueDescription
ABS
Acrylonitrile Butadiene Styrene
Brass
Brass
Copper
Copper
DI
Ductile Iron
MS
Mild Steel
PVC
PolyVinylChloride
PE
Polyethylene
AC
Asbestos Cement - Existing Infrastructure Only
M_1
A new material not in the schema as agreed with the receiving entity
M_2
A new material not in the schema as agreed with the receiving entity
Other
Another material not in the Schema
Unknown
Material unknown at time of data submission
Lining
enum
Optional
The internal corrosion protection method employed on the fitting material.
Accepted Values
ValueDescription
CL
Cement Lined Normal(default for Ductile Iron and Mild Steel)
CL_SR
Cement Lined - Sulphate Resistant (DI and MS)
CL_AC
Cement Lined - Calcium Aluminate (DI and MS)
PVC
Plasticised PVC (includes Humes Plastiline)
FBE
Fusion Bonded Epoxy
Unlined
Unlined
Unknown
Lining type unknown at time of data submission
Other
Another type of liner that is not currently in the Schema
Protection
enum
Optional
The external corrosion protection method employed on the fitting material.
Accepted Values
ValueDescription
FBE
Fusion Bonded Epoxy
FBPE
Fusion Bonded Polyethylene (Includes the product known commercially as Sintakote)
Plastic Wrapped
Plastic Wrapped
Concrete Encased
Concrete Encased
Tape Wrapped
Wrapped in pipe and flange protection anti-corrosion tape. Commonly a synthetic fabric tape coated with a neutral petrolium compound.
Uncoated
Uncoated
Epoxy
Epoxy paint or coating
P_1
A new protection type not yet in the schema as agreed with the data receiving entity
P_2
A new protection type not yet in the schema as agreed with the data receiving entity
Zinc
Galvanized or zinc painted
Zinc-Aluminium Alloy
Zinc Aluminium alloy coating (Petair Saint-Gobain)
Unknown
Protection type unknown at time of data submission
Other
Another type of protection not covered by the schema
BodySize_mm
positiveInteger
Required
The nominal diameter of the largest pipe entering the fitting. Although not constrained, software may use the simpleType water_fittings_boresize for a starting list of values
BranchSize_mm
positiveInteger
Optional
The nominal diameter of the smallest pipe entering the fitting. Although not constrained, software may use the simpleType water_fittings_boresize for a starting list of values
Rotation
Float_Direction
Optional
Rotation angle (cartesian - anti-clockwise 0 degrees = East)
WaterQuality
enum
Required
The quality of the water being carried by the network to which the fitting is a part
Accepted Values
ValueDescription
Drinking Water
Drinking-quality (potable) water for normal mains supply by the municipal water service provider
Recycled Aplus
Class A+ tertiary treated with reverse osmosis recycled water for supply via dual reticulation for permitted interior and exterior uses
Recycled A
Class A tertiary treated recycled water for supply via dual reticulation for permitted exterior uses
Treated Effluent
Treated Effluent to class B through class D for irrigation only
Rain Water
Rain Water collected directly into the system for irrigation
Raw Water
Untreated water from a watercourse or pond used to feed a water treatment plant or irrigation system
Ground Water
Untreated water from bores used to feed a water treatment plant or irrigation system
Process Water
Non-potable process water of some description
Other
Pipe conveying some other kind of water (not recycled class B and below which is considered as treated sewage effluent)
Unknown
Type of water carried by this pipe is unknown at time of submission