StormWater / ADAC Version v4.1

Pit

Represents a stormwater maintenance hole or pit feature.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
PitNumber String_32
Required

The pit identifier.

Use enum
Required

Purpose of the feature in the network.

Accepted Values
ValueDescription
Manhole Maintenance or access point
Pit Pit only - no access
RoofwaterInspectionChamber RoofwaterInspectionChamber
ChamberConstruction enum
Required

Method of chamber construction.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
ChamberSize enum
Required

Represents the essential dimensions of the chamber. Contains a choice of structures that pertain to different configurations.

RectangularDimensions of a rectangular chamber.
Length_mm positiveInteger
Required

Length in millimetres.

Width_mm positiveInteger
Required

Width in millimetres.

LidType enum
Required

The type of lid or grate covering the opening.

Accepted Values
ValueDescription
GalvGrate Galvanised Steel Grate.
CastIronGrate Cast Iron Grate.
CircCastIron Circular Cast Iron Lid.
CircConcInfill Circular Concrete Infill Lid.
SqrCastIron Square Cast Iron Lid.
SqrConcInfill Square Concrete Infill Lid.
RectCastIron Rectangular Cast Iron.
RectConcInfill Rectangular Concrete Infill Lid.
CIFrameConcInfill Cast Iron Frame Concrete Infill.
PrecastCoverSlabs Long Rectangular Concrete Cover Slabs (usually 2 per pit).
HydroflowGrate Hydroflow Grate.
CastIronBikePedSafeGrate Cast Iron Bicycle and Pedestrian Safe Grate.
DimensionsPointLevels_m structure
Required

Calls in the standard elements for surface and invert levels.

StructureStructure
SurfaceLevel_m float
Required

Surface level in metres AHD of this feature.

InvertLevel_m float
Required

Invert level in metres AHD of this feature.

Depth_m Float_Positive_NonZero
Required

The depth of the structure in metres. May be user-entered, or auto-calculated as the difference between the surface level and the invert level of the pit.

Inlet boolean
Optional

Represents a surface inlet to the pit. Set to nil if this pit does not have a surface inlet.

truetrue
InletConfig enum
Required

Positioning of the inlet against the pit.

Accepted Values
ValueDescription
Left Left hand side
Center Center
Right Right hand side
InletType enum
Required

The type of inlet employed.

Accepted Values
ValueDescription
IPWEAFieldInletType1 IPWEA - Grated Field Inlet Type One
IPWEAFieldInletType2600x600 IPWEA - Grated Field Inlet Type Two 600mm x 600mm
IPWEAFieldInletType2600x900 IPWEA - Grated Field Inlet Type Two 600mm x 900mm
IPWEAKILGully IPWEA - Kerb Inline Gully Pit
IPWEALILGully IPWEA - Lip Inline Gully Pit
OTHERAntiPondingGully Council Specific Anti-Ponding Gully
OTHERBroPit Council Specific Bro Pit
OTHERDrainway Council Specific Drainway Pit
OTHERFieldInletType1 Council Specific Field Inlet (900mm x 900mm)
OTHERFieldInletType2600x600 Council Specific Field Inlet (600mm x 600mm)
OTHERFieldInletType2600x900 Council Specific Field Inlet (600mm x 900mm)
OTHERKILGully Council Specific Kerb Inline Gully Pit
OTHERLILGully Council Specific Lip Inline Gully Pit
OTHERSideEntryPit Council Specific Side Entry Pit
OTHERTrenchGrate Council Specific Trench Grate
Lintel boolean
Optional

Represents the pit lintel. Set to nil if this pit does not have a lintel.

truetrue
LintelConstruction enum
Required

The type of inlet employed.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
LintelLength_m Float_Positive_NonZero
Required

Represents the length in metres of the lintel.

Accepted Values
ValueDescription
1.2 1.2m
2.1 2.1m
2.4 2.4m
3 3m
3.6 3.6m
4.8 4.8m
OutletType enum
Required

The type of outlet for this pit.

Accepted Values
ValueDescription
Dry Dry
Surcharge Surcharge
FireRetardant boolean
Required

True of false value indicating whether fire retardant measures are incorporated.

Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)