Skip to main content
StormWater / ADAC Version v5.0.1

GPTComplex

Represents a commerial or custom in-pit GPT unit. Must occur collocated with a pit.

ADAC Versions

Attributes

Required and optional XML attributes
Sqid_Id String_32
Optional

The string identifier of the device, as it would appear on a plan.

Construction enum
Required

GPTComplex

CommercialCommercial
Manufacturer String_64
Optional

The Manufacturer of the unit

ModelNumber String_64
Optional

The standard code, model number or part number for the unit

Size enum
Optional

The planimetric size of the device. This element is nillable because the manufacturer and model are mandatory, but if capture software designers wish to automatically populate the sizes from a list of known device models, then all of the appropriate dimensions must be supplied

RectangularPlanimetric dimensions of a rectangular device.
Length_mm positiveInteger
Required

Length in millimetres

Width_mm positiveInteger
Required

Width in millimetres

Function1 enum
Required

The first function of the WSUD point. The device must have at least one function. Usually Gross Pollutant Capture will be the most important function.

Accepted Values
ValueDescription
Gross Pollutant Capture Gross Pollutant Capture
Sediment Capture Sediment Capture
Oil / Grit Separation Oil / Grit Separation
Filtration Filtration of fine particulates from stormwater before discharging to a downstream drainage system.
Function2 enum
Optional

The second function of the WSUD point, if applicable

Accepted Values
ValueDescription
Gross Pollutant Capture Gross Pollutant Capture
Sediment Capture Sediment Capture
Oil / Grit Separation Oil / Grit Separation
Filtration Filtration of fine particulates from stormwater before discharging to a downstream drainage system.
Function3 enum
Optional

The third function of the device, if applicable

Accepted Values
ValueDescription
Gross Pollutant Capture Gross Pollutant Capture
Sediment Capture Sediment Capture
Oil / Grit Separation Oil / Grit Separation
Filtration Filtration of fine particulates from stormwater before discharging to a downstream drainage system.
US_PipeDiameter_mm positiveInteger
Optional

The upstream pipe diameter in millimetres

DS_PipeDiameter_mm positiveInteger
Optional

The downstream pipe diameter in millimetres

SurfaceLevel_m float
Required

The surface level at the top of the device

US_InvertLevel_m float
Required

Invert level of this pipe end (in metres against the vertical datum).

DS_InvertLevel_m float
Required

Invert level of this pipe end (in metres against the vertical datum).

CleanoutLevel_m float
Required

The level to which the device must be cleaned out, in metres against the vertical datum of the project.

Depth_m Float_Positive_NonZero
Optional

The depth, in metres, of the device.

SumpDepth_m Float_Positive_NonZero
Optional

The depth, in metres, of the sump, if applicable

HasFilterMedia boolean
Optional

True if the device has filtration media or a filter capsule installed.

HasBasket boolean
Optional

True if the device has a litter basket installed.

HasBoards boolean
Optional

True if the device has drop-boards or penstock installed.

DesignFlow_m3s Float_Positive_NonZero
Required

Design Flow in cubic metres per second

MaxContaminantVolume_m3 Float_Positive_NonZero
Optional

Maximum contaminant retention volume in cubic metres.

MaxInternalVolume_m3 Float_Positive_NonZero
Optional

Maximum internal volume in cubic metres.

MaintenanceCycle_mnths positiveInteger
Optional

The minimum maintenance cycle in months (refer to specifications)

Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)