The string identifier of the device, as it would appear on a plan.
GPTComplex
Represents a commerial or custom in-pit GPT unit. Must occur collocated with a pit.
Attributes
Required and optional XML attributesGPTComplex
The Manufacturer of the unit
The standard code, model number or part number for the unit
The planimetric size of the device. This element is nillable because the manufacturer and model are mandatory, but if capture software designers wish to automatically populate the sizes from a list of known device models, then all of the appropriate dimensions must be supplied
Length in millimetres
Width in millimetres
Diameter in millimetres
The dimensions of the device. This element is mandatory for custom built devices. The appropriate dimensions must be supplied
Length in millimetres
Width in millimetres
Diameter in millimetres
The first function of the WSUD point. The device must have at least one function. Usually Gross Pollutant Capture will be the most important function.
Accepted Values
The second function of the WSUD point, if applicable
Accepted Values
The third function of the device, if applicable
Accepted Values
The upstream pipe diameter in millimetres
The downstream pipe diameter in millimetres
The surface level at the top of the device
Invert level of this pipe end (in metres against the vertical datum).
Invert level of this pipe end (in metres against the vertical datum).
The level to which the device must be cleaned out, in metres against the vertical datum of the project.
The depth, in metres, of the device.
The depth, in metres, of the sump, if applicable
True if the device has filtration media or a filter capsule installed.
True if the device has a litter basket installed.
True if the device has drop-boards or penstock installed.
Design Flow in cubic metres per second
Maximum contaminant retention volume in cubic metres.
Maximum internal volume in cubic metres.
The minimum maintenance cycle in months (refer to specifications)
Rotation angle (cartesian - anti-clockwise 0 degrees = East)