StormWater / ADAC Version v5.0.1

EndStructurePolyline

Represents a stormwater endstructure feature as a Point object.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
StructureID String_32
Required

The identifier for this end structure. Usually the textual identifier it would be labelled with on the face of a plan.

StructureLevel_m float
Required

The surface level of the structure in metres against the vertical datum for the project.

EndWall boolean
Required

Data structure representing the end wall. Set to nil if this End Structure does not have an end wall.

truetrue
Type enum
Required

The type of stormwater end wall structure.

Accepted Values
ValueDescription
PipeEndwall PipeEndwall
BoxEndwall BoxEndwall
MultiCellPipeEndwall MultiCellPipeEndwall
MultiCellBoxEndwall MultiCellBoxEndwall
MultiCellPipeAndBoxEndwall MultiCellPipeAndBoxEndwall
SlopingPipeEndwall SlopingPipeEndwall
Size String_32
Required

Define the number of cells and sizes penetrating the End Structure. ie. 3/750 or 2/1200x900 or 2/900x600+1/600.

Length_m Float_Positive_Zero
Required

Represents the length in metres of the end wall.

Height_m Float_Positive_Zero
Required

Represents the height in metres of the end wall.

Thickness_m Float_Positive_Zero
Required

Represents the Thickness in metres of the end wall.

Material enum
Required

The predominant construction material of the end wall structure.

Accepted Values
ValueDescription
Concrete Concrete
ReinforcedConcrete ReinforcedConcrete
GroutedRock GroutedRock
RevetmentMattress RevetmentMattress
NA Not Applicable – To be used if not present
Construction enum
Required

The method of construction of the end wall structure.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
WingWall boolean
Required

Data structure representing the wing wall. Set to nil if this End Structure does not have any wing walls.

truetrue
LWW_Length_m Float_Positive_Zero
Required

Represents the length in metres of the left wing wall.

LWW_Height_m Float_Positive_Zero
Required

Represents the height in metres of the left wing wall.

LWW_Thickness_m Float_Positive_Zero
Required

Represents the thickness in metres of the left wing wall.

LWW_Material enum
Required

The predominant construction material of the left wing wall.

Accepted Values
ValueDescription
Concrete Concrete
ReinforcedConcrete ReinforcedConcrete
GroutedRock GroutedRock
RevetmentMattress RevetmentMattress
NA Not Applicable – To be used if not present
LWW_Construction enum
Required

The method of construction of the left wing wall.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
RWW_Length_m Float_Positive_Zero
Required

Represents the length in metres of the right wing wall.

RWW_Height_m Float_Positive_Zero
Required

Represents the height in metres of the right wing wall.

RWW_Thickness_m Float_Positive_Zero
Required

Represents the thickness in metres of the right wing wall.

RWW_Material enum
Required

The predominant construction material of the right wing wall.

Accepted Values
ValueDescription
Concrete Concrete
ReinforcedConcrete ReinforcedConcrete
GroutedRock GroutedRock
RevetmentMattress RevetmentMattress
NA Not Applicable – To be used if not present
RWW_Construction enum
Required

The method of construction of the right wing wall.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
Apron structure
Required

Data structure representing the apron.

StructureStructure
Apron_Width_m Float_Positive_Zero
Required

Represents the width in metres of apron on the End Structure.

Apron_Thickness_m Float_Positive_Zero
Required

Represents the thickness in metres of apron on the End Structure.

Apron_Area_m2 Float_Positive_Zero
Required

Represents the area in square metres of apron on the End Structure.

Apron_Material enum
Required

The predominant construction material of apron on the End Structure.

Accepted Values
ValueDescription
Grassed Grassed
Concrete Concrete
StonePitched StonePitched
PlacedRock PlacedRock
GroutedRock GroutedRock
RevetmentMattress RevetmentMattress
RockFilledWireBasket RockFilledWireBasket
Geotextile Geotextile
ConcreteEnergyDissepiment ConcreteEnergyDissepiment
NA Not Applicable – To be used if not present
Apron_Construction enum
Required

The method of construction of apron on the End Structure.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
GrateType enum
Optional

Type of grate used, if applicable.

Accepted Values
ValueDescription
Baffled Baffled
Grated Grated
StillingBasin StillingBasin
None No grate fitted
TideGate enum
Optional

Type of tide or flood gate used, if applicable.

Accepted Values
ValueDescription
FibreglassProprietary FibreglassProprietary
Fabricated Fabricated
Controlled Controlled
Rubber Rubber
None No tidegate fitted