Sewerage / ADAC Version v5.0.1

PipePressure

Element representing a sewer pipe pressurised (rising main).

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
Use enum
Required

The function of this pipe in the network.

Accepted Values
ValueDescription
Disused Non-pressure (gravity) pipe that is no longer in use but still present.
Effluent Pipe conveying treated effluent (usually from a treatment plant).
Reuse A pipe conveying low-grade (class B and below) treated effluent for reuse. Class A and A+ should use the water feature classes.
Rising A standard rising main or pressure sewer.
Scour A pipe maintained under pressure to scour a pressure main to a discharge point. Gravity scours should use the non-pressure pipe feature class.
Vacuum A gravity sewer flowing into a vacuum sewerage system (vacuum system pipes are part of the pressure pipe schema).
PressureSewerCollection The connection pipe from a household proprietary pressure sewer pump unit to the external pressure main.
Unknown Use unknown at time of submission.
Other A use other than those specified above.
Diameter_mm positiveInteger
Required

Nominal pipe diameter in millimetres.

Material enum
Required

Pipe material.

Accepted Values
ValueDescription
ABS Acrylonitrile Butadiene Styrene.
GRP Glass Reinforced Plastic (includes the product known commercially as Hobas).
DI Ductile Iron.
MS Mild Steel.
PE100 Polyethylene (100).
PE80B Polyethylene (80B).
PVC-M PolyVinylChloride (Modified).
PVC-O PolyVinylChloride (Oriented).
PVC-U PolyVinylChloride (Unplasticised).
AC Asbestos Cement (not for new works - legacy pipes only).
FRC Fibre Reinforced Concrete.
M_1 New material not included in schema as agreed with data recieiving entity.
M_2 New material not included in schema as agreed with data recieiving entity.
Unknown Material type unknown at time of data submission.
Other A material not included in schema types provided above.
Class enum
Required

The pipe class as specified by the manufacture. Pipe class refers to the wall thickness and performance of the material.

Accepted Values
ValueDescription
SN5000 Class SN5000.
SN8000 Class SN8000.
SN10000 Class SN10000.
PN1 Class PN1.
PN6 Class PN6.
PN6.3 Class PN6.3.
PN8 Class PN8.
PN9 Class PN9.
PN10 Class PN10.
PN12 Class PN12.
PN12.5 Class PN12.5.
PN16 Class PN16 - default for PE_100, PVC_O and PVC_M.
PN18 Class PN18.
PN20 Class PN20.
PN35 Class PN35 (Standard for ductile iron).
FLCL Class FLCL (ductile iron flanged class).
X Class X (Reinforced Concrete).
Y Class Y (Reinforced Concrete).
Z Class Z (Reinforced Concrete).
4.8mm 4.8mm wall thickness Class (Mild Steel).
5mm 5mm wall thickness Class (Mild Steel).
6mm 6mm wall thickness Class (Mild Steel).
7mm 7mm wall thickness Class (Mild Steel).
8mm 8mm wall thickness Class (Mild Steel).
9mm 9mm wall thickness Class (Mild Steel).
10mm 10mm wall thickness Class (Mild Steel).
12mm 12mm wall thickness Class (Mild Steel).
16mm 16mm wall thickness Class (Mild Steel).
Unknown Unknown at time of submission.
Other A class other than provided above.
Lining enum
Optional

The internal corrosion protection method employed on the pipe material.

Accepted Values
ValueDescription
CL Cement Lined Normal. Cetrifugally spun cement mortar (default for Ductile Iron and Mild Steel).
CL_SR Cement Lined - Sulphate Resistant (DI and MS).
CL_AC Cement Lined - Calcium Aluminate (DI and MS).
PVC Plasticised PVC (includes Humes Plastiline).
FBE Fusion Bonded Epoxy.
Unlined Unlined
Unknown Lining type unknown at time of data submission.
Other Another type of liner that is not currently in the Schema.
Protection enum
Optional

The external corrosion protection method employed on the pipe material.

Accepted Values
ValueDescription
FBE Fusion Bonded Epoxy.
FBPE Fusion Bonded Polyethelene (Includes the product known commercially as Sintakote).
PlasticWrapped PlasticWrapped
TapeWrapped TapeWrapped
ConcreteEncased ConcreteEncased
Sheathed Sheathed
EpoxyPaint EpoxyPaint
Uncoated Uncoated
P_1 A new protection type not yet included in the Schema as agreed with the receiving entity.
P_2 A new protection type not yet included in the Schema as agreed with the receiving entity.
Zinc Galvanized or zinc painted.
ZincAluminiumAlloy Zinc Aluminium alloy coating (Petair Saint-Gobain).
Unknown Protection Type unknown at time of data submission.
Other Another type of protection not covered by the schema.
JointType enum
Required

Pipe to pipe join method.

Accepted Values
ValueDescription
RRJ Rubber Ring.
RRRJ Rubber Ring Restrained Joint (Ductile Iron).
SWJ Solvent Welded Joint (PVC)
WJ Welded Joint (Mild Steel pipe)
FJ Flanged Joint.
MCJ Mechanical Compression Joint (PE pipe and Copper).
BW Butt Weld (PE pipe).
EFW Electrofusion Weld (PE pipe).
JT_1 A new joint type not yet included in the Schema used by agreement with the receiving entity..
Unknown Joint type unknown at time of data submission.
Other A joint type not already included in the above choices.
Alignment_m Float_Positive_NonZero
Optional

Average offset distance in metres from casdastral boundary to the main.

Depth_m float
Optional

Nominal depth in metres to the top of the pipe.

Embedment enum
Optional

Embedment type.

Accepted Values
ValueDescription
Natural Pipe laid directly on natural in-situ material.
GBH Granular bed and haunch.
GBS Granular bed and surround.
GBSonConc Granular bed and surround on concrete support.
GBSonGTP Granular bed and surround on geo-textile pillow.
GBSonCSS Granular bed and surround on cement stabilised support.
GBSonPiles Granular bed and surround on piles.
CemStabBS Cement stabilised bed and surround.
ConcBS Concrete bed and surround.
ConcBSonPiles Concrete bed and surround on piles.
Enveloped Within an enveloper pipe.
AboveGround Pipe is above ground on piers or a bridge deck.
None Thrust bored or Trenchless method.
Unknown Embedment Type unknown at time of data submission.
Other Another type of embedment type that is not already includesd in the standard types.
EB_1 A non-standard or new type of embedment as agreed with the data receiving entity.
EB_2 A non-standard or new type of embedment as agreed with the data receiving entity.
RockExcavated boolean
Optional

Value indicating whether rock was excavated from the pipe channel.

Length_m Float_Positive_NonZero
Optional

Actual material length of the pipe. Not the horizontal length of the geometry.