Sewerage / ADAC Version v4.1

PipeNonPressure

Element representing a sewer pipe non-pressurised. Includes all gravity reticulation and trunk gravity mains.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
LineNumber String_32
Optional

The sewer line identifier.

Use enum
Required

The function of this pipe in the network.

Accepted Values
ValueDescription
ConduitPipe Conduit Pipe (enveloper), which does not connect hydraulically with the reticulation system.
Disused Non-pressure (gravity) pipe that is no longer in use but still present.
Effluent Pipe conveying treated effluent (usually from a treatment plant).
Overflow A pipe that directs excessive sewer flows to another system or the external environment.
Reuse A pipe conveying low-grade (class B and below) treated effluent for reuse. Class A and A+ should use the water feature classes.
Stub A short length of pipe for a future connection pipe that is not connected at its upsteam end at time of data submission.
Trunk A larger size sewer as defined by the receiving entity's standard definition.
Vent A pipe to a vent pipe or deodorising apparatus, which not primarily designed to convey sewage.
Syphon A gravity sewer that flows uphill over part of its length due to syphonic action.
Vacuum A gravity sewer flowing into a vacuum sewerage system (vacuum system pipes are part of the pressure pipe schema).
Reticulation A standard reticulation sewer that is not a trunk sewer.
Diameter_mm positiveInteger
Required

Nominal pipe diameter in millimetres.

Material enum
Required

The pipe material.

Accepted Values
ValueDescription
UPVC Unplasticised Poly Vinyl Chloride. Default Value.
ABS Acrylonitrile Butadiene Styrene.
CastIron CastIron
Concrete Concrete
DICL Ductile Iron Concrete Lined.
FRC Fibre Reinforced Concrete.
GRP Glass Reinforced Plastic (includes the product known commercially as Hobas).
MSCL Mild Steel Cement Lined.
OPVC Oriented Poly Vinyl Chloride.
PE Polyethylene.
RCP Reinforced Concrete Pipe.
SWPP Structural Wall Polypropylene Pipe.
BC Box Culvert.
HDPE High Density Polyethylene.
PVC Poly-Vinyl Chloride.
VCH VC Hepworth.
VCN VC Naylor.
VC Vitrified Clay.
MDPE Medium Density Poly-Ethylene.
Class enum
Required

The pipe class as specified by the manufacture. Pipe class refers to the wall thickness and performance of the material.

Accepted Values
ValueDescription
SN8 Class SN8 (Class Sewer Extra Heavy). Default Value.
4 Class 4.
6 Class 6.
9 Class 9.
12 Class 12.
16 Class 16.
18 Class 18.
20 Class 20.
PN6.3 Class PN6.3.
PN8 Class PN8.
PN10 Class PN10.
PN12.5 Class PN12.5.
SN4 Class SN4 (Class Sewer Heavy).
SN5000 Class SN5000.
SN8000 Class SN8000.
SN10000 Class SN10000.
X Class X (Reinforced Concrete).
Y Class Y (Reinforced Concrete).
Z Class Z (Reinforced Concrete).
Protection enum
Required

The external corrosion protection method employed on the pipe material.

Accepted Values
ValueDescription
FBE Fusion Bonded Epoxy.
Sintakote Sintakote
Wrapped Wrapped
Encased Encased
Sheathed Sheathed
DimensionsInvertLevels_m structure
Required

Calls in the standard elements for upstream and downstream invert levels.

StructureStructure
US_InvertLevel_m float
Required

Invert level in metres AHD of this pipe end.

DS_InvertLevel_m float
Required

Invert level in metres AHD of this pipe end.

DimensionsSurfaceLevels_m structure
Required

Calls in the standard elements for upstream and downstream surface levels.

StructureStructure
US_SurfaceLevel_m float
Required

Surface level in metres AHD vertically above this pipe end.

DS_SurfaceLevel_m float
Required

Surface level in metres AHD vertically above this pipe end.

Alignment_m Float_Positive_NonZero
Optional

Average offset distance in metres from casdastral boundary to the main.

AverageDepth_m float
Required

Nominal depth in metres to the top of the pipe.

Embedment enum
Required

Embedment type from WSAA Sewerage Codes.

Accepted Values
ValueDescription
Type 1 WSAA Sewerage embedment type 1.
Type 2 WSAA Sewerage embedment type 2.
Type 3 WSAA Sewerage embedment type 3.
Type 4 WSAA Sewerage embedment type 4.
Type 5 WSAA Sewerage embedment type 5.
Type 6 WSAA Sewerage embedment type 6.
Type 7 WSAA Sewerage embedment type 7.
Type 8 WSAA Sewerage embedment type 8.
Type 9 WSAA Sewerage embedment type 9.
Type 10 WSAA Sewerage embedment type 10.
Type 11 WSAA Sewerage embedment type 11.
Type 12 WSAA Sewerage embedment type 12.
Type 13 WSAA Sewerage embedment type 13.
JointType enum
Required

Pipe to pipe join method.

Accepted Values
ValueDescription
RubberRing RubberRing
SolventWeld SolventWeld
ElectrofusionWeld ElectrofusionWeld
RockExcavated boolean
Optional

Value indicating whether rock was excavated from the pipe channel.

PipeGrade Float_Positive_Zero
Required

Pipe grade as a percentage. Derivable as the difference in invert levels divided by the horizontal length (not the length of pipe) multiplied by 100.

Length_m Float_Positive_NonZero
Required

Actual material length of the pipe. Not the horizontal length of the geometry.