Sewerage / ADAC Version v4.2

Connection

Element representing a sewer property connection.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
DimensionsPointLevels_m structure
Required

Call in standard elements for levels at the inspection opening. Level in meters against the vertical datum for this project.

StructureStructure
SurfaceLevel_m float
Required

Surface level in metres AHD of this feature.

InvertLevel_m float
Required

Invert level in metres AHD of this feature.

Use enum
Required

The function of the house connection in the network..

Accepted Values
ValueDescription
House House Drain - standard sanitary drain conveying sewage only.
Combined Combined House Drain - a sanitary drain conveying both sewage and storm water in a combined sewerage system.
Diameter_mm positiveInteger
Required

The nominal diameter of the connection conduit.

Material enum
Required

The pipe material.

Accepted Values
ValueDescription
UPVC Unplasticised Poly Vinyl Chloride. Default Value.
CastIron CastIron
Concrete Concrete
DICL Ductile Iron Concrete Lined.
FRC Fibre Reinforced Concrete.
FRP Fibre Reinforced Plastic.
MPVC Modified Poly-Vinyl Chloride.
OPVC Oriented Poly Vinyl Chloride.
PE Polyethylene.
VC Vitrified Clay.
MDPE Medium Density Poly-Ethylene.
MaterialClass enum
Required

The pipe class as specified by the manufacture. Pipe class refers to the wall thickness and performance of the material.

Accepted Values
ValueDescription
SH Sewer Heavy.
SEH Sewer Extra Heavy.
Length_m Float_Positive_NonZero
Required

The material length in metres of the house connection branch conduit.

Type enum
Required

The physical configuration of the valve.

Accepted Values
ValueDescription
SlopedBranch WSAA - Sloped Branch connection.
RampRiser WSAA - Ramp Riser connection.
JumpUp WSAA - Jump Up connection.
Stub WSAA - Connection straight into Maintenance Hole.
TwinJumpUp WSAA - Twin Jump Up connection.
TwinRampRiser WSAA - Twin Ramp Riser connection.
Chainage_m Float_Positive_Zero
Required

The distance in metres from the centre of the downstream manhole to the point of connection of the offshoot branch.

Offset_m Float_Positive_NonZero
Required

The distance measured square from the centre of the sewer main to the point of connection.

LineNumber String_32
Optional

The line identifier of the sewer main.

DSMHID String_32
Optional

Downstream manhole identifier.

IO_Distance_m Float_Positive_NonZero
Required

Distance from a point perpendicular to the inspection opening to the centre of the downstream manhole along the axis of the sewer main.

SO_Nearest_m Float_Positive_NonZero
Required

Perpendicular distance from the inspection opening to the nearest cadastral boundary.

SO_Other_m Float_Positive_NonZero
Required

Perpendicular distance from the inspection opening to the next nearest cadastral boundary.

SedimentTrap boolean
Required