OpenSpace / ADAC Version v4.2

ElectricalFitting

Retired

Represents an electrical fitting point feature, including lighting, whether freestanding or fixed to an existing structure.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
Type enum
Required

The type of Electrical Component eg: Light, Switch Board, Power Outlet.

Accepted Values
ValueDescription
Light Light
Pit Pit
Pole Pole
PowerOutlet PowerOutlet
SwitchBoardMeterBox SwitchBoardMeterBox
Material enum
Required

The material type of the component eg: Aluminium, Steel.

Accepted Values
ValueDescription
Aluminium Aluminium
Concrete Concrete
Plastic Plastic
StainlessSteel StainlessSteel
GalvanisedSteel GalvanisedSteel
PowderCoatedSteel PowderCoatedSteel
Stone Stone
Wood Wood
EnergySource enum
Required

The type of Power Source eg; Mains, Solar.

Accepted Values
ValueDescription
Main Main
Solar Solar
Manufacturer String_32
Required

The Manufacturer of the unit.

ModelNumber String_32
Required

The standard code, model number or part number for the unit.