Electrical / ADAC Version v6.0.0

Switchboard

Represents an electrical switchboard feature.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
Type enum
Required

The type of switchboard.

Accepted Values
ValueDescription
Control Board Control Board for housing Control gear, including but not limited to Electricity Meters, Pump Control, Lighting Control, etc.
Distribution Board Distribution Board.
Main Switchboard Main Switchboard.
Traffic Controller Board Controller Board for Traffic Signals.
EnclosureMaterial enum
Required

The material of the switchboard enclosure.

Accepted Values
ValueDescription
Aluminium Aluminium.
Plastic Plastic.
Sheet Steel Sheet Steel.
Stainless Steel Stainless Steel.
EnclosureCoating enum
Optional

The coating of the switchboard enclosure.

Accepted Values
ValueDescription
Galvanised Galvanised.
Nil Nil.
Paint Paint.
Powdercoat Powdercoat.
EnclosureConstruction enum
Optional

Enclosure construction for a switchboard.

Accepted Values
ValueDescription
Bell IP Rated enclosure to house a Switchboard inside a Pit.
Custom Custom.
Generic Meter Box Residential/Commercial Box incorporation Electricity Meter and Switchboard.
Package Board Off the shelf plastic Switchboard enclosure.
Panel Board Off the shelf Metal Switchboard enclosure, which incorporates Switchboard. But not a Electricity Meter.
Pillar Electricity Pillar, aka 'Green Boy'.
Pole Inside a Pole.
MountType enum
Optional

The mounting type used to fix the switchboard.

Accepted Values
ValueDescription
Plinth Plinth.
Pit Located in a Pit.
Pole Pole (Attached to or mounted inside).
Post Post (Mounted on or attached to)
Structure Attached to Structure e.g. Building, Shelter, Wall, Fence etc.
Surface Surface Mounted.
ElectricityTariff enum
Required

The Electricity tariff of the switchboard.

Accepted Values
ValueDescription
Metered Metered.
Rate 3 Regulated Unmetered Public Safety Lighting.
Solar Solar.
Tariff 91 Unregulated Unmetered Supply (Non-contestable Electricity Retailer).
SupplyArrangement enum
Optional

Supply phase.

Accepted Values
ValueDescription
1 Phase 1 Phase.
3 Phase 3 Phase.
TypeOfSupply enum
Optional

Type of supply to switchboard.

Accepted Values
ValueDescription
N/A Standalone e.g. solar.
Overhead Supply Overhead Supply.
Underground Supply Underground Supply.
Height_mm positiveInteger
Required

The height of the enclosure measured in the vertical in millimetres.

Width_mm positiveInteger
Required

The width of the enclosure measured horizontally in millimetres.

Depth_mm positiveInteger
Required

The depth of the enclosure in millimetres.

NoOfDoors positiveInteger
Optional

The number of doors on the enclosure.

MeterNumber String_64
Optional

The supply authority electrical meter asset number. When multiple meters are present, meter numbers are to be recorded ie. 123456, 567890.

NationalMeterIdentifier String_64
Optional

Identification number for the connection to the National Electricity Network. NMI number in most States will be an 10 or 11 digit number, such as 44012345678 or two letters followed by digits, such as QB044123456.

PointOfSupply String_32
Optional

Details of Point of Supply.

IP_Rating String_64
Optional

Refers to the IP (Ingress Protection) of switchboard. The rating is used to describe levels of sealing protection on electrical enclosures against solid objects and moisture.

Manufacturer String_64
Optional

The Manufacturer of the unit.

ModelNumber String_64
Optional

The standard code, model number or part number for the unit.