Skip to main content
StormWater / ADAC Version v6.0.0

NonGPTSimple

Represents a Water Sensitive Urban Design point feature

ADAC Versions

Attributes

Required and optional XML attributes
Sqid_Id String_32
Optional

The string identifier of the device, as it would appear on a plan.

Construction enum
Required

The construction method

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
Manufacturer String_64
Optional

The Manufacturer of the unit

ModelNumber String_64
Optional

The standard code, model number or part number for the unit

TreatmentMeasure enum
Required

The treatment measure employed

Accepted Values
ValueDescription
Aquifer Storage Tank Aquifer Storage Tank
Energy Dissipater An installation in a drainage line, usually of concrete or stone, designed to dissipate the kinetic energy of flowing stormwater, to minimise its potential for erosion and damage. Often placed immediately downstream of an endstructure, but may conceivably be anywhere needed in a drainage line.
Floating Boom Foating Boom
Infiltration Pond Infiltration measure designed to promote infiltration of appropriately treated water to surrounding soils. The primary function of these devices is runoff volume control rather than pollutant removal.
Infiltration Tank Infiltration measure designed to promote infiltration of appropriately treated water to surrounding soils. The primary function of these devices is runoff volume control rather than pollutant removal.
Rubble Pit A rubble pit designed to promote infiltration of untreated runoff to surrounding soils.
Sand Filter A sand filter is a sand layer designed to filter fine particulates from stormwater before discharging to a downstream drainage system.
Sediment Forebay A Sediment Forebay, usually associated with a WSUD area to intercept coarse sediment.
Function1 enum
Required

The first function of the WSUD point. Must be supplied.

Accepted Values
ValueDescription
Sediment Capture Sediment Capture
Sand Filtration Sand Filtration occurs in a sand layer designed to filter fine particulates from stormwater before discharging to a downstream drainage system.
Infiltration Infiltration measures typically consist of holding pond or tank designed to promote infiltration of appropriately treated water to surrounding soils. The primary function of these devices is runoff volume control rather than pollutant removal.
Aquifer Storage Aquifer Storage
Energy Dissipation The dissipation of kinetic energy from flowing storwater to reduce its potential for erosion and damage.
Function2 enum
Optional

The second function of the WSUD point, if applicable

Accepted Values
ValueDescription
Sediment Capture Sediment Capture
Sand Filtration Sand Filtration occurs in a sand layer designed to filter fine particulates from stormwater before discharging to a downstream drainage system.
Infiltration Infiltration measures typically consist of holding pond or tank designed to promote infiltration of appropriately treated water to surrounding soils. The primary function of these devices is runoff volume control rather than pollutant removal.
Aquifer Storage Aquifer Storage
Energy Dissipation The dissipation of kinetic energy from flowing storwater to reduce its potential for erosion and damage.
Function3 enum
Optional

The third function of the device, if applicable

Accepted Values
ValueDescription
Sediment Capture Sediment Capture
Sand Filtration Sand Filtration occurs in a sand layer designed to filter fine particulates from stormwater before discharging to a downstream drainage system.
Infiltration Infiltration measures typically consist of holding pond or tank designed to promote infiltration of appropriately treated water to surrounding soils. The primary function of these devices is runoff volume control rather than pollutant removal.
Aquifer Storage Aquifer Storage
Energy Dissipation The dissipation of kinetic energy from flowing storwater to reduce its potential for erosion and damage.
Length_mm positiveInteger
Required

The length of the device

Width_mm positiveInteger
Optional

The width of the device

MaintenanceCycle_mnths positiveInteger
Optional

The minimum maintenance cycle in months. This is the revisit interval for maintenance or inspection, if applicable.

Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)