Skip to main content
WaterSupply / ADAC Version v5.0.1

ServiceFitting

Represents a domestic service fitting.

ADAC Versions

Attributes

Required and optional XML attributes
Type enum
Required

The type of service fitting

Accepted Values
ValueDescription
Control Panel Irrigation control panel which may or may not be hydraulically connected
Dog Bowl Fixed animal drinking bowl attached to customer owned water connection
Drinking Fountain Drinking Fountain or bubbler to provide drinking water to patrons
Drip Line Fixed perforated pipe for drip irrigation
Fountain Decorative A decorative fountain
Filling Station Card-accessed water delivery point for commercial access
Filter In line filter to prevent irrigation line blockages
Goose Neck Downward pointing outlet on a vertical riser
Hot Water System Hot Water System. Normally attached to a structure.
Nipple Simple riser or short length of small bore pipe providing a point of discharge
Other Some other irrigation fitting - do not use for pipe fittings, valves pumps etc as these exist in other feature classes
Pop Up Sprinkler Pop-up type sprinkler head
Shower Open air public shower point, such as may be found at beachside parks
Spray Nozzle Fixed Irrigation sprayer, sprinkler, bubbler or drip nozzle
Tap Water delivery tap. Not a stopcock or control valve
BelowGround boolean
Optional

Is the fitting below ground

WaterSaver boolean
Optional

Does the fitting employ waste minimisation technology (other than auto shut-off)

AutoShutOff boolean
Optional

Does the fitting employ auto shut-off technology

Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)

WaterQuality enum
Required

The quality/source of the water being supplied through the service fitting.

Accepted Values
ValueDescription
Drinking Water Drinking-quality (potable) water for normal mains supply by the municipal water service provider
Recycled Aplus Class A+ tertiary treated with reverse osmosis recycled water for supply via dual reticulation for permitted interior and exterior uses
Recycled A Class A tertiary treated recycled water for supply via dual reticulation for permitted exterior uses
Treated Effluent Treated Effluent to class B through class D for irrigation only
Rain Water Rain Water collected directly into the system for irrigation
Raw Water Untreated water from a watercourse or pond used to feed a water treatment plant or irrigation system
Ground Water Untreated water from bores used to feed a water treatment plant or irrigation system
Process Water Non-potable process water of some description
Other Pipe conveying some other kind of water (not recycled class B and below which is considered as treated sewage effluent)
Unknown Type of water carried by this pipe is unknown at time of submission