Conduit

Represents an communication conduit feature

ADAC Versions

Attributes

Required and optional XML attributes
Use enum
Required

The primary use for the conduit

Accepted Values
ValueDescription
Coaxial Coaxial
Data - Other Data - Other
Fibre Fibre
Marked for Future Use Marked for Future Use
Material enum
Required

The conduit material type eg: PVC, Galvanised etc

Accepted Values
ValueDescription
Galvanised Galvanised
HDPE High Density Polyethylene
Other Other - define other in notes field
PE Polyethylene
PVC Polyvinyl Chloride
Placement enum
Optional

This describes where/how the communication conduit is placed

Accepted Values
ValueDescription
Mixed Mixed
Submerged Submerged (water)
Surface Mounted Surface Mounted
Underground Underground
Protection enum
Optional

The type of conduit protection used eg: Concrete encased, warning tape only

Accepted Values
ValueDescription
Concrete Batts Concrete Batts
Concrete Encased Concrete Encased
Galvanised Steel Galvanised Steel
Pavers Pavers
Polymetric Cable Cover Polymetric Cable Cover
Rubber Matting Rubber Matting
Warning Tape Warning Tape
Size_mm enum
Required

The size of the conduit in millimetres ie. 16mm-63mm OD, 80mm-150mm ID

Accepted Values
ValueDescription
16 16mm
20 20mm
25 25mm
32 32mm
50 50mm
63 63mm
100 100mm
110 110mm
Other Other - define other size in notes field
TraceWire boolean
Optional

True or false value indicating whether a trace wire is present

Configuration String_64
Optional

Utilised when there is multiple conduit diameters utilised in the same trench. The configuration of the conduits laid in the trench, ie Quantity x Size eg. 2 x 80mm + 1 x 50mm

NoOfConduits positiveInteger
Required

Total number of communication conduits on alignment

AverageDepth_mm positiveInteger
Optional

The average depth of the communication conduit in the trench/run in millimetres